Article Detail

Home > Article Detail
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2011, v.2 no.2, pp.57-60
https://doi.org/10.5478/MSL.2011.2.2.057
Park Sujin (Korea Atomic Energy Research Institute)
Park Jong-Ho (Korea Atomic Energy Research Institute)
Lee Myung Ho (Korea Atomic Energy Research Institute)
Song Kyuseok (Korea Atomic Energy Research Institute)
  • Downloaded
  • Viewed

Abstract

As background significantly affects measurement accuracy and a detection limit in determination of the traceamounts of uranium, it is necessary to determine the impurities in the Lexan detector film for single particle measurements bythermal ionization mass spectrometry coupled with fission track technique (FT-TIMS). We have prepared various micro sizes ofthe blank Lexan detector film using a micromanipulation technique for uranium measurements by TIMS. Few tens of fg of uraniumbackground with no remarkable dependency on the film sizes were observed in the blank Lexan films with the sizes from50 × 50 μm2 to 300 × 300 μm2. Based on the determination of the uranium background in the Lexan film, any background correctionis necessary in the isotopic analysis of a uranium single particle with micron sizes when the particle bearing Lexan film is dissectedwith less than 300 × 300 μm2 size. The isotopic analysis of a uranium particle in U030 standard material using TIMS was carriedout to verify the applicability of the Lexan film to the single particle analysis with high accuracy and precision.

keywords
Uranium, Background, TIMS, Particle Analysis, Isotopic Analysis, Safeguards


Reference

1

Donohue, D. L.. (1998). . J. Alloy Compd, 271-273, 11-.

2

Lee, C. G. (2006). . Jpn. J. Appl. Phys, 45, 294-.

3

Esaka, K. T. (2004). . Jpn, J. Appl. Phys, 43, L915-.

4

Lee, M. H. (2011). . Radiat. Meas, 46, 409-.

5

Shen, Y. (2008). . Radiat. Meas, 43, S299-.

6

Lee, C. G.. (2007). . J. Radioanal. Nucl. Chem, 272, 299-.

7

Lee, M. H.. (2005). . Radiat. Meas, 40, 37-.

8

Cohen, A. S.. (1992). . Int. J. Mass Spectrom. Ion Process, 116, 71-.

9

Heumann, K. G.. (1995). . Analyst, 120, 1291-.

10

Rubin, K. H. (2001). . Chemical Geology, 175, 723-.

11

Richter, S.. (2003). . Int. J. Mass Spectrom, 229, 181-.

12

Suzuki, D.. (2010). . Int. J. Mass Spectrom, 294, 23-.

13

Jeon, Y. S. (2008). . Analytical Science and Technology, 21, 487-.

14

Wolff, J. C.. (1996). . Int. J. Mass Spectrom. Ion Process, 156, 67-.

15

Heumann, K. G.. (1982). . Int. J. Mass Spectrom. Ion Phys, 45, 87-.

16

Suzuki, D.. (2010). . Int. J. Mass. Spectrom, 294, 23-.

17

Kraiem, M.. (2011). . Anal. Chim. Acta, 688, 1-.

Submission Date
2011-06-01
Revised Date
2011-06-07
Accepted Date
2011-06-08
상단으로 이동