Article Detail

Home > Article Detail
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2021, v.12 no.2, pp.31-40
https://doi.org/10.5478/MSL.2021.12.2.31
Chang Shu-Han (Food and Drug Administration, Ministry of Health and Welfare)
Ho Hui-Yu (Food and Drug Administration, Ministry of Health and Welfare)
Zang Chi-Zong (Food and Drug Administration, Ministry of Health and Welfare)
Hsu Ya-Hui (Food and Drug Administration, Ministry of Health and Welfare)
Lin Mei-Chih (Food and Drug Administration, Ministry of Health and Welfare)
Tseng Su-Hsiang (Food and Drug Administration, Ministry of Health and Welfare)
Wang Der-Yuan (Food and Drug Administration, Ministry of Health and Welfare)
  • Downloaded
  • Viewed

Abstract

Probable human carcinogenic compounds nitrosamines, have been detected as by-product impurities in sartan phar-maceuticals in recent years which has drawn worries for medication safety. To provide a sensitive and effective method for the quality control of sartan pharmaceuticals, this study established a feasible gas chromatography–tandem mass spectrometry (GC–MS/MS) method for simultaneous determination of 13 nitrosamines. The target analytes were separated on a DB-WAX Ultra Inert column (30 m × 0.25 mm; i.d., 0.25 µm) and were then subjected to electron impact ionization in multiple reaction moni-toring mode. The established method was validated and further employed to analyze authentic samples. Limits of detection (LODs) and limits of quantification (LOQs) of the 13 nitrosamines were 15-250 ng/g and 50-250 ng/g, respectively, which also exhibited intra-day and inter-day accuracies of 91.4-104.8%, thereby satisfying validation criteria. Five nitrosamines, viz., N-nitrosodiethylamine, N-nitrosodimethylamine, N-nitrosodiphenylamine, N-nitrosomorpholine, and N-nitrosopiperidine were detected at concentrations above their LODs in 68 positive samples out of 594 authentic samples from seven sartans.

keywords
angiotensin II type 1 receptor blockers, carcinogens, gas chromatography, mass spectrometry, nitrosamines


Submission Date
2021-04-22
Revised Date
2021-05-11
Accepted Date
2021-05-18